Nikos Parissis, DDS, PhD; Christos Angelopoulos, DDS, MS; Stephen Mantegari, DDS, MD; Stelios Karamanis, DDS; Farah Masood, DDS, MS; Anastasios Tsirlis, DDS, PhD

Aim: To compare digital panoramic images acquired for the presurgical assessment of third molars captured with a storage phosphor-based system with conventional film panoramic radiographs.
Methods and Materials: A total of 51 pairs of digital and conventional panoramic images, made simultaneously, were included in this study. The images were evaluated for diagnostic quality prior to third molar surgery by two experienced oral surgeons and rated with a four-point grading scale.
Results: Despite the fact that conventional panoramic images were rated higher than the digital images, the difference was not statistically significant.
Conclusions: Conventional and digital panoramic images were found to be of comparable image quality with regard to their diagnostic contribution to third molar surgery.
Clinical Significance: This study is contributory to understanding differences in image quality between digital and conventional panoramic radiography for certain diagnostic tasks. The lack of significant differences in image quality may be an endorsement for digital panoramic radiography.
Keywords: Digital radiography, panoramic radiography, image quality
Citation: Parissis N, Angelopoulos C, Mantegari S, Karamanis S, Masood F, Tsirlis A. A Comparison of Panoramic Image Quality between a Digital Radiography Storage Phosphor System and a Film-Based System. J Contemp Dent Pract [Internet]. 2010 Jan; 11(1):009-016. Available from: http://www.thejcdp.com/journal/view/volume11-issue1-parissis.
©2010, The Journal of Contemporary Dental Practice. Seer Publishing