The Journal of Contemporary Dental Practice

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 13 , ISSUE 2 ( March-April, 2012 ) > List of Articles

RESEARCH ARTICLE

Relating the Marginal Fit of the Castings to the Accuracy of the Impressions made from Laminated Hydrocolloid Impression Technique: A Comparative Study

Manish Sinha, Bhavana Thakur, Ajay Gaikwad, Lalitkumar Dnyandeo Chaudhari, Adwait Kulkarni, Harshal Kulkarni

Citation Information : Sinha M, Thakur B, Gaikwad A, Chaudhari LD, Kulkarni A, Kulkarni H. Relating the Marginal Fit of the Castings to the Accuracy of the Impressions made from Laminated Hydrocolloid Impression Technique: A Comparative Study. J Contemp Dent Pract 2012; 13 (2):167-172.

DOI: 10.5005/jp-journals-10024-1115

Published Online: 01-10-2012

Copyright Statement:  Copyright © 2012; The Author(s).


Abstract

Aim

Relating the marginal fit of the castings, to the accuracy of the impression produced using laminated hydrocolloid impression technique, alginate and double-mixed polyvinyl siloxane. Basic objective of the study is to check the feasibility of the use of laminated hydrocolloid impression technique in the fixed partial denture.

Materials and methods

The precisely machined metal die was designed to simulate standard complete metal crown preparation. The preparation was mounted on cylindrical base of 20 mm length and diameter of 10 mm. Seven impressions were made from the each impression material onto the metal die, and total 21 impressions were obtained from all three impression materials, which were poured by the die stone, and stone die was prepared. Wax patterns were fabricated on stone dies obtained from each impression and then casting was done. All the castings were checked for the marginal fit on metal die after applying a uniform standardized load of 30 pounds using measuring microscope.

Results

Result revealed that the marginal fit of the castings obtained from group II (laminated hydrocolloid technique) and group III (double-mix polyvinyl polysiloxane) did not show the significant difference between the two of them. Marginal gap of the castings obtained from group I are significantly greater in comparison to the castings obtained from groups II and III (p < 0.01).

Conclusion

Group II (laminated hydrocolloid technique) impression material may be the choice of many clinicians over group III (double-mix polyvinyl polysiloxane) impression material. Group I (alginate impression material), though very cost-effective and easy to handle may not able to produce accurate results.

Clinical significance

The study gives overview of the best impression material that can be used clinically. Laminated hydrocolloid technique is the technique of choice.

How to cite this article

Sinha M, Thakur B, Gaikwad A, Chaudhari LD, Kulkarni A, Kulkarni H. Relating the Marginal Fit of the Castings to the Accuracy of the Impressions made from Laminated Hydrocolloid Impression Technique: A Comparative Study. J Contemp Dent Pract 2012;13(2):167-172.


PDF Share
  1. The combination of hydrocolloid/alginate impression. JADA 1983;106:194-95.
  2. A study of accuracy hydrocolloid impression. J Prosthet Dent 1956;6(1):80-86.
  3. Bond strength and accuracy of combined reversible-irreversible hydrocolloid impression system. J Prosthet Dent 1992;67(5):621-32.
  4. Accuracy of impression materials for complete arch fixed partial dentures. J Prosthet Dent 1988;59(3):288-89.
  5. Accuracy and bond strength of reversible with irreversible hydrocolloid impression system: A comparative study. J Prosthet Dent 1992;68(4):578-84.
  6. Porcelain fused to metal: Tooth preparation and coping design. J Prosthet Dent 1973;30:28-36.
  7. Comparison of the dimensional accuracy of a combined reversible/irreversible hydrocolloid impression system with commonly used impression materials. J Prosthet Dent 1984;52(6):795-99.
  8. The combined reversible/irreversible hydrocolloid impression system: Clinical implication. J Prosthet Dent 1981;46(1):48-58.
  9. Dimensional accuracy of combined irreversible and reversible hydrocolloid system. J Prosthet Dent 1988;59(4):404-09.
  10. Comparison of elastomeric impression materials used in fixed prosthodontics. J Prosthet Dent 1981;45(1):89-94.
  11. Accuracy and dimensional stability of combined hydrocolloid impression system. J Prosthet Dent 1992;67(6):873-78.
  12. Accuracy and bond strength of combined agar/alginate hydrocolloid impression system. J Prosthet Dent 1986;55(6):1-6.
  13. A comparison of impression materials for complete arch fixed partial denture. J Prosthet Dent 1991;65(1):165-69.
  14. Check bite impression using irreversible alginate/reversible hydrocolloid combination. J Prosthet Dent 1997;77(1):83-85.
  15. Disinfection procedures: Their effect on the dimensional accuracy and surface quality of irreversible hydrocolloid impression materials and gypsum casts. Dental Materials 2002;18(2):103-10.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.