A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study

T Shankar, N Venugopal Rao, Snigdha Gowd, Syed Tauqheer Ahmed, V Vinod, M Vikas Goud

Citation Information : Shankar T, Rao NV, Gowd S, Ahmed ST, Vinod V, Goud MV. A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study. J Contemp Dent Pract 2012; 13 (6):842-849.

DOI: 10.5005/jp-journals-10024-1240

Published Online: 01-04-2013

Copyright Statement:  Copyright © 2012; The Author(s).


Abstract

Aim

The aim of this study is to evaluate the dimensional accuracy of heat polymerized acrylic resin denture base clamped by the conventional method and by new-press technique and cured by long curing cycle.

Materials and methods

In this study, a total of 60 standardized maxillary record bases were fabricated with seven reference points as follows:

• Point A

Incisive papilla,

• Point B and C

Canine region on either side

• Point E and G

Midpoint of tuberosities on either side

• Point F

Midpoint of the line joining the two tuberosities

• Point D

Midpoint between the line joining A and F

Group A

Ten maxillary record bases were fabricated by conventional clamping method and cured by long curing cycle.

Group A’

Ten maxillary record bases were fabricated by New Press or RS tension clamping method and cured by long curing cycle.

The distances between the reference points, i.e. A-B, A-C, A-D, D-F, B-E, C-G, E-F, F-G, B-D, D-G, C-D, D-E of all three thermoplastic denture base plates were measured and recorded with the help of travelling microscope and were used for comparison with the measured and recorded readings of processed acrylic denture bases. The data obtained was analyzed by using the one-way analysis of variance and HSD Multiple Comparison Test.

Results

The overall results of the study indicate that among all the denture bases cured by the two clamping systems and the long curing cycle, group A‘ were the most dimensionally stable, followed by control group A.

Conclusion

The study concluded that the denture bases fabricated by the New Press method using the long curing cycle would produce the most dimensionally stable denture bases.

How to cite this article

Shankar T, Gowd S, Ahmed ST, Vinod V, Goud MV, Rao NV. A Comparative Evaluation of the Dimensional Accuracy of Heat Polymerized Acrylic Resin Denture Base Clamped by the Conventional Method and by New-press Technique and Cured by Long Curing Cycle: An in vitro Study. J Contemp Dent Pract 2012;13(6):842-849.


PDF Share
  1. From vulcanite to vinyl, a history of resins in restorative dentistry. J Prosthet Dent 2002;87:364-79.
  2. History of resins in dentistry. Dent Clin North Am 1975;19:211-22.
  3. Restorative Dental Materials (11th edn). St. Louis, MO, Mosby 2002:636-89.
  4. Changes caused by processing complete denture. J Prosthet Dent 1951;1:551-59.
  5. Posterior peripheral seal distortion related to processing temperature. J Prosthet Dent 1981:598-601.
  6. Effect of a new tension system, used in acrylic resin flasking, on the dimensional stability of denture bases. J Prosthet Dent 2002;88(3):285-89.
  7. Effect of curing cycle on acrylic denture base glass transition temperature. J Dent 1991;19(4):245-48.
  8. Tooth movement and dimensional change of denture base materials using two investment methods; J Prosthet Dent 1980:44(4):368-73.
  9. Linear dimensional variability of three denture base resins after processing and in water storage. J Prosthet Dent 1992:68(1):196-200.
  10. The effect of three processing cycles on some physical and chemical properties of heat-cured acrylic resins. J Prosthet Dent 1989;61(4):510-17.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.