The Journal of Contemporary Dental Practice

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 14 , ISSUE 3 ( May-June, 2013 ) > List of Articles

RESEARCH ARTICLE

Comparison of Galvanic Corrosion Potential of Metal Injection Molded Brackets to that of Conventional Metal Brackets with Nickel-Titanium and Copper Nickel-Titanium Archwire Combinations

S Chidambaram, D Praveen Kumar Varma, K Baburam Reddy, D Ravindranath, M Rajendra Prasad

Citation Information : Chidambaram S, Varma DP, Reddy KB, Ravindranath D, Prasad MR. Comparison of Galvanic Corrosion Potential of Metal Injection Molded Brackets to that of Conventional Metal Brackets with Nickel-Titanium and Copper Nickel-Titanium Archwire Combinations. J Contemp Dent Pract 2013; 14 (3):488-495.

DOI: 10.5005/jp-journals-10024-1350

Published Online: 01-10-2013

Copyright Statement:  Copyright © 2013; The Author(s).


Abstract

Aim

The aim of the study is to investigate the galvanic corrosion potential of metal injection molding (MIM) brackets to that of conventional brackets under similar in vitro conditions with nickel-titanium and copper nickel-titanium archwires.

Materials and methods

Twenty-five maxillary premolar MIM stainless steel brackets and 25 conventional stainless steel brackets and archwires, 0.16 inch, each 10 mm length, 25 nickeltitanium wires, 25 copper nickel-titanium wires were used. They were divided into four groups which had five samples each. Combination of MIM bracket with copper nickel-titanium wire, MIM bracket with nickel-titanium wire and conventional stainless steel brackets with copper nickel-titanium wire and conventional stainless steel brackets with nickel-titanium wires which later were suspended in 350 ml of 1 M lactic acid solution media. Galvanic corrosion potential of four groups were analyzed under similar in vitro conditions. Precorrosion and postcorrosion elemental composition of MIM and conventional stainless steel bracket by scanning electron microscope (SEM) with energy dispersive spectroscope (EDS) was done.

Results

MIM bracket showed decreased corrosion susceptibility than conventional bracket with copper nickeltitanium wire. Both MIM and conventional bracket showed similar corrosion resistance potential in association with nickel-titanium archwires. It seems that both brackets are more compatible with copper nickel-titanium archwires regarding the decrease in the consequences of galvanic reaction. The EDS analysis showed that the MIM brackets with copper nickel-titanium wires released less metal ions than conventional bracket with copper nickeltitanium wires.

Conclusion

MIM brackets showed decreased corrosion susceptibility, copper nickel-titanium archwires are compatible with both the brackets than nickel-titanium archwires.

Clinical significance

Clinically MIM and conventional brackets behaved more or less similarly in terms of corrosion resistance. In order to decrease the corrosion potential of MIM brackets, more precise manufacturing technique should be improved to get a more smoother surface finish.

How to cite this article

Varma DPK, Chidambaram S, Reddy KB, Vijay M, Ravindranath D, Prasad MR. Comparison of Galvanic Corrosion Potential of Metal Injection Molded Brackets to that of Conventional Metal Brackets with Nickel-Titanium and Copper Nickel-Titanium Archwire Combinations. J Contemp Dent Pract 2013;14(3):488-495.


PDF Share
  1. Galvanic Corrosion between various combinations of orthodontic brackets and archwire. Am J Orthod 2001 Jul;140(1):25-31.
  2. Comparative study on the corrosion behaviour of Ti-Nb and TMA alloys for dental application in various artificial saliva. Mater Sci Engineer 2011;C31:702-711.
  3. Galvanic corrosion of metal injected molded (MIM) and conventional brackets with nickel-titanium and copper nickeltitanium archwires. Angle Orthod 2007 Mar;77(2):355-360.
  4. Corrosion behaviour and galvanic coupling of titanium and welded titanium in LiBr solutions. Corrosion Sci 2007 Mar;49(3):1000-1026.
  5. Variation in surface characteristics and corrosion behaviour of metal bracket and wires in different electrolyte solutions. Eur J Orthod 2010 Oct;32(5):555-560.
  6. Nickel concentration in the saliva of patients with nickel-titanium orthodontic appliances. Am J Orthod Dentofacial Orthop 2009 Jan;135(1):59-65.
  7. Nickel hypersensitivity reaction before, during and after orthodontic therapy. Am J Orthod Dentofacial Orthop 1998 Jun;113(6):655-660.
  8. Is galvanic corrosion between titanium alloy and stainless steel spinal implant a clinical concern? Spine J 2004 Jul-Aug;4(4):379-387.
  9. Salivary nickel and chromium in subjects with different types of fixed orthodontic appliances. Am J Orthod Dentofac Orthop 1997 Jun;111(6):595-598.
  10. Surface corrosion of nitinol and stainless steel under clinic conditions. Angle Orthod 1981;51(4):319-324.
  11. Corrosion of orthodontic appliances–should we care? Am J Orthod Dentofacial Orthop 2008 Apr;113(4):584-592.
  12. Composition and in vitro corrosion of orthodontic appliance. Am J Orthod Dentofac Orthop 1992 Jun;101(6):525-532.
  13. Skinners science of dental materials. 9th ed. Philadelphia: WB Saunders Co;1991. 349-358 p.
  14. Characterization and cytotoxicity of ions released from stainless steel and nickel-titanium orthodontic alloys. Am J Orthod Dentofacial Orthop 2004 Jan;125(1):24-29.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.