Citation Information :
Patel RK, Pai SA, Nagaraj T, Kohli A, KJ MJ, BG S. Linear Dimensional Changes of Five Interocclusal Recording Materials When Immersed in Two Disinfectants for Different Time Intervals. J Contemp Dent Pract 2019; 20 (6):732-737.
Aim: In this study, we intend to compare the linear dimensional changes of interocclusal recording media by immersing them in disinfectant solutions at different time intervals.
Materials and methods: Five interocclusal recording materials were used for this study and were grouped according to material types, namely wax, zinc oxide eugenol impression paste, polyether, polyvinyl siloxane, and bisacryl bite registration material. Each material was manipulated and injected into a stainless steel die. The materials were divided into 5 groups with 5 subgroups of 10 samples with a total of 250 samples. The samples were subjected to immersion in 2% glutaraldehyde and 0.5% sodium hypochlorite each for 30 and 60 minutes. Linear dimensional changes of the samples were tested by measuring the distance between points A and B at different time intervals by means of a stereomicroscope and compared with the control group.
Results: Bisacryl showed the least linear dimensional change when immersed in both the solutions.
Conclusion: Bisacryl (Luxabite) presented no linear dimensional change at both time intervals as opposed to the other materials, hence, it is most accurate.
Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc 1988;116:241–248. https://jada. ada.org/article/S0002-8177(88)62021-6/abstract
Rani L. Sterilization protocols in dentistry – a review. J Pharm Sci Res 2016;8(6):558–564.
Badrian H, Davoudi A, et al. The effect of spraying different disinfectants on condensation silicone impressions. JIPS 2015;45(3):263–267.
Gounder R. Comparison of disinfectants by immersion and spray atomization techniques on the linear dimensional stability of different interocclusal recording materials: an in vitro study. Eur J Dent 2016;10:7–15. DOI: 10.4103/1305-7456.175684.
Hemalatha R, Ganapathy D. Disinfection of dental impression – a current overview. J Pharm Sci Res 2016;8(7):661–664. https://www.jpsr. pharmainfo.in/Documents/Volumes/vol8Issue07/jpsr080716018.pdf
Anusavice K. Philips science of dental materials. 11th edn. India: Saunders Publication, 2003.
Marcinak CF, Young FA, et al. Linear dimensional changes in elastic impression materials. J Dent Res 1980;59:11(5)2–5. DOI: 10.1177/00220345800590070701.
Pagnano Vde O, Bezzon OL, et al. Clinical evaluation of interocclusal recording materials in bilateral free end cases. Braz Dent J 2005;16:140–144.
Squier RS. Jaw relation records for fixed prosthodontics. Dent Clin N Am 2004;48:471–486. DOI: 10.1016/j.cden.2004.01.001.
Freilich MA, Altieri JV, et al. Principles for selecting interocclusal records for articulation of dentate and partially dentate casts. J Prosthet Dent 1992;68:361–367.
Lassila V. Comparison of five interocclusal recording materials. J Prosthet Dent 1986;55(2):215–218.
Michalakis KX, Pissiotis A, et al. An experimental studyon particular physical properties of several interocclusal recording media. Part I: consistency prior to setting. J Prosthodont 2004;13:42–46. DOI: 10.1111/j.1532-849X.2004.04005.x.
Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc 1988;116:241–248.
Rani L. Sterilization protocols in dentistry – a review. J Pharm Sci Res 2016;8(6):558–564.
Tejo SK, Kumar A, et al. A comparative evaluation of dimensional stability of three types of interocclusal recording materials-an in vitro multi-centre study. Head Face Med 2012;8:27. DOI: 10.1186/1746-160X- 8-27.