The Journal of Contemporary Dental Practice

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 24 , ISSUE 4 ( April, 2023 ) > List of Articles

ORIGINAL RESEARCH

Analysis of Shaping Abilities of Rotary File Systems in Oval Canals with Moderate Root Curvature: A Randomized Controlled Ex Vivo Study

Anchu Rachel Thomas, Tripuravaram Vinay Kumar Reddy, Jee Yee Tan, Sharron Ee Jia Qing, Chee Sing Qing, Lim Ying Xuan, AR Vivekananda Pai

Keywords : Canal transportation, Centering ability, Cone-beam computed tomography, Oval-shaped canals, TruNatomy shapers, XP-endo shapers

Citation Information : Thomas AR, Reddy TV, Tan JY, Qing SE, Qing CS, Xuan LY, Pai AV. Analysis of Shaping Abilities of Rotary File Systems in Oval Canals with Moderate Root Curvature: A Randomized Controlled Ex Vivo Study. J Contemp Dent Pract 2023; 24 (4):221-227.

DOI: 10.5005/jp-journals-10024-3471

License: CC BY-NC 4.0

Published Online: 15-06-2023

Copyright Statement:  Copyright © 2023; The Author(s).


Abstract

Aim: The purpose of this study was to evaluate and compare the canal transportation tendencies and centering ability of the TruNatomy shaper (TN) and XP-endo shaper (XPS) rotary systems in oval-shaped canals with moderate root curvature (15°–25°), using cone-beam computed tomography (CBCT) imaging. Materials and methods: Sixty single-rooted permanent human teeth were chosen after considering the inclusion and exclusion criteria. The teeth were divided into two groups (n = 30). The test group was instrumented with TN files and the other with XPS according to manufacturer's instructions. CBCT images were taken before and after instrumentation to record the root canal distances from mesial, distal, buccal, and lingual borders of the root at 3, 5, and 7 mm distances from the root apex using a specific formula. Statistical analysis was done using the Statistical Package for the Social Sciences software program, version 20.0. The data were analyzed using the unpaired t test. Results: Both TN and XPS were safe for use in oval-shaped canals with moderate root curvature. However, the XPS showed higher buccolingual transportation as compared with TN at 3 mm from the apex and higher mesiodistal transportation at 3 and 5 mm levels from the apex as compared with TN. Conclusion: Canal transportation has been detected in both systems; however, the values obtained were within the safe range (<0.3 mm). Overall, no significant difference was observed between TN and XPS (p > 0.05) in their canal transportation tendencies and centering ability. Clinical significance: The study assesses the canal centering and transportation tendencies of the recently launched TN rotary system in extracted teeth with a combination of morphologies. The findings of the study are significant clinically as minimum transportation of the canal, minimal dentin removal, efficient disinfection, and three-dimensional obturation of the root canal are considered important factors in deciding the prognosis of endodontic therapy.


HTML PDF Share
  1. Schäfer E, Dammaschke T. Development and sequelae of canal transportation. Endod Topics 2006;15(1):75–90. DOI: 10.1111/j.1601-1546.2009.00236.x.
  2. Shah DY, Wadekar SI, Dadpe AM, et al. Canal transportation and centering ability of protaper and self-adjusting file system in long oval canals: an ex-vivo cone-beam computed tomography analysis. J Conserv Dent 2017;20(2):105–109. DOI: 10.4103/0972-0707.212234.
  3. De-Deus G, Reis C, Beznos D, et al. Limited ability of three commonly used thermoplasticized gutta-percha techniques in filling oval-shaped canals. J Endod 2008;34(11):1401–1405. DOI: 10.1016/j.joen.2008.08.015.
  4. Alves FR, Almeida BM, Neves MA, et al. Disinfecting oval-shaped root canals: effectiveness of different supplementary approaches. J Endod 2011;37(4):496–501. DOI: 10.1016/j.joen.2010.12.008.
  5. Metzger Z, Teperovich E, Zary R, et al. The self-adjusting file (SAF). Part 1: respecting the root canal anatomy – A new concept of endodontic files and its implementation. J Endod 2010;36(4):679–690. DOI: 10.1016/j.joen.2009.12.036.
  6. Velozo C, Silva S, Almeida A, et al. Shaping ability of XP-endo shaper and ProTaper Next in long oval-shaped canals: a micro-computed tomography study. Int Endod J 2020;53(7):998–1006. DOI: 10.1111/iej.13301.
  7. Medeiros TC, Lima CO, Barbosa AFA, et al. Shaping ability of reciprocating and rotary systems in oval-shaped root canals: a microcomputed tomography study. Acta Odontol Latinoam 2021;34(3):282–288. DOI: 10.54589/aol.34/3/282.
  8. Carvalho MC, Zuolo ML, Arruda-Vasconcelos R, et al. Effectiveness of XP-endo finisher in the reduction of bacterial load in oval-shaped root canals. Braz Oral Res 2019;33:e021. DOI: 10.1590/1807-3107bor-2019.vol33.0021.
  9. Jafarzadeh H, Abbott PV. Ledge formation: review of a great challenge in endodontics. J Endod 2007;33(10):1155–1162. DOI: 10.1016/j.joen.2007.07.015.
  10. Kuzekanani M. Nickel-titanium rotary instruments: development of the single-file systems. J Int Soc Prev Community Dent 2018;8(5):386–390. DOI: 10.4103/jispcd.JISPCD_225_18.
  11. Riyahi AM, Bashiri A, Alshahrani K, et al. Cyclic fatigue comparison of TruNatomy, Twisted File, and ProTaper Next rotary systems. Int J Dent 2020;2020:3190938. DOI: 10.1155/2020/3190938.
  12. Alfadley A, Alrajhi A, Alissa H, et al. Shaping ability of XP Endo shaper file in curved root canal models. Int J Dent 2020:4687045. DOI: 10.1155/2020/4687045.
  13. Nagendrababu V, Murray PE, Ordinola-Zapata R, et al. PRILE 2021 guidelines for reporting laboratory studies in endodontology: explanation and elaboration. Int Endod J 2021;54(9):1491–1515. DOI: 10.1111/iej.13565.
  14. Hasheminia SM, Farhad A, Sheikhi M, et al. Cone-beam computed tomographic analysis of canal transportation and centering ability of single-file systems. J Endod 2018;44(12):1788–1791. DOI: 10.1016/j.joen.2018.09.011.
  15. Malur MH, Chandra A. Curvature height and distance of MB canal of mandibular molar with Schneider angle and its comparison with canal access angle. J Oral Biol Craniofac Res 2018;8(3):212–216. DOI: 10.1016/j.jobcr.2017.07.002.
  16. Dotto L, Sarkis Onofre R, Bacchi A, et al. Effect of root canal irrigants on the mechanical properties of endodontically treated teeth: A scoping review. J Endod 2020;46(5):596–604.e3. DOI: 10.1016/j.joen.2020.01.017.
  17. Kiran KK, Hemant V, Pujar MA. Tamase Aishwarya S, Umesh S. Comparative evaluation of shaping ability of TruNatomy and protaper gold files in curved canals using cone-beam computed tomography: an in-vitro study. IP Ind J Conserv Endod 2021;6(2):101–105.
  18. Pacheco-Yanes J, Gazzaneo I, Pérez AR, et al. Transportation assessment in artificial curved canals after instrumentation with Reciproc, Reciproc Blue, and XP-endo Shaper Systems. J Investig Clin Dent 2019;10(3):e12417. DOI: 10.1111/jicd.12417.
  19. Shukri BM. A comparative study to evaluate canal transportation and centering ability of simulated curved canals prepared by XP-Shaper, WaveOne Gold and ProTaper NEXT files. Mustansiria Dent J 2018;15(1).
  20. Werdina VB, Bahnam IN. Evaluation of centering ability of XP endo shaper, Edge Evolve and Hyflex CM in simulated curved canals: (A comparative study). EDJ 2019;2(1):130–140. DOI: 10.15218/EDJ.2019.02.
  21. Poly A, Tseng WL, Marques F, et al. Micro-computed tomographic analysis of the shaping ability of XP-Endo Shaper in oval-shaped distal root canals of mandibular molars. Eur Endod J 2021;6(3):271–277. DOI: 10.14744/eej.2021.44153.
  22. Van der Vyver PJ, Vorster M, et al. Minimally invasive endodontics using a new single-file rotary system-Part 2. International Dentistry (African ed.) 2019;10:4–20.
  23. Kim H, Jeon SJ, Seo MS. Comparison of the canal transportation of ProTaper gold, WaveOne gold, and TruNatomy in simulated double-curved canals. BMC Oral Health 2021;21(1):533. DOI: 10.1186/s12903-021-01854-z.
  24. Kumar M, Paliwal A, Manish K, et al. Comparison of canal transportation in TruNatomy, ProTaper Gold, and Hyflex electric discharge machining file using cone-beam computed tomography. J Contemp Dent Pract 2021;22(2):117–121. DOI: 10.5005/jp-journals-10024-2970.
  25. Kabil E, Katić M, Anić I, et al. Micro-computed evaluation of canal transportation and centering ability of 5 rotary and reciprocating systems with different metallurgical properties and surface treatments in curved root canals. J Endod 2021;47(3):477–484. DOI: 10.1016/j.joen.2020.11.003.
  26. Pérez Morales MLN, González Sánchez JA, Olivieri JG, et al. Micro-computed tomographic assessment and comparative study of the shaping ability of 6 nickel-titanium files: an in vitro study. J Endod 2021;47(5):812–819. DOI: 10.1016/j.joen.2020.12.021.
  27. Wu MK, Fan B, Wesselink PR. Leakage along apical root fillings in curved root canals. Part I: effects of apical transportation on seal of root fillings. J Endod 2000;26(4):210–216. DOI: 10.1097/00004770-200004000-00003.
  28. Poly A, AlMalki F, Marques F, et al. Canal transportation and centering ratio after preparation in severely curved canals: analysis by micro-computed tomography and double-digital radiography. Clin Oral Investig 2019;23(12):4255–4262. DOI: 10.1007/s00784-019-02870-8.
  29. Zuolo ML, Zaia AA, Belladonna FG, et al. Micro-CT assessment of the shaping ability of four root canal instrumentation systems in oval-shaped canals. Int Endod J 2018;51(5):564–571. DOI: 10.1111/iej.12810.
  30. Swain MV, Xue J. State of the art of micro-CT applications in dental research. Int J Oral Sci 2009;1(4):177–188. DOI: 10.4248/IJOS09031.
  31. Ludlow JB, Davies-Ludlow LE, Brooks SL, et al. Dosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT. Dento Maxillo Fac Radiol 2006;35(4):219–226. DOI: 10.1259/dmfr/14340323.
  32. Hatcher DC. Operational principles for cone-beam computed tomography. J Am Dent Assoc 2010;141;Suppl 3:3S-6S. DOI: 10.14219/jada.archive.2010.0359.
  33. Alodeh MH, Doller R, Dummer PM. Shaping of simulated root canals in resin blocks using the step-back technique with K-files manipulated in a simple in/out filling motion. Int Endod J 1989;22(3):107–117. DOI: 10.1111/j.1365-2591.1989.tb00908.x.
  34. Briseño Marroquin B, Sobarzo-Navarro V, Devens S. The influence of different engine-driven, sound ultrasound systems and the canal master on root canal preparation: an in vitro study. Int Endod J 1993;26(3):190–197. DOI: 10.1111/j.1365-2591.1993.tb00792.x.
  35. Briseño BM, Sonnabend E. The influence of different root canal instruments on root canal preparation: an in vitro study. Int Endod J 1991;24(1):15–23. DOI: 10.1111/j.1365-2591.1991.tb00865.x.
  36. Barbosa-Ribeiro M, Albergaria SJ, Malvar MD, et al. Canal transportation and centering ability of curved root canals prepared using rotary and reciprocating systems. Braz J Oral Sci 2015;14(3):214–218. DOI: 10.1590/1677-3225v14n3a08.
  37. Taylor JR. Error analysis. 2nd ed. Sausalito, CA: University Science Books; 1997. p. 20.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.