The Journal of Contemporary Dental Practice

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 9 , ISSUE 5 ( July, 2008 ) > List of Articles

RESEARCH ARTICLE

Clinical Evaluation of Dose Reduction on Image Quality of Panoramic Radiographs

Meryem Toraman Alkurt, Likay Peker, Gülten Usalan, Bülent Altunkaynak

Citation Information : Alkurt MT, Peker L, Usalan G, Altunkaynak B. Clinical Evaluation of Dose Reduction on Image Quality of Panoramic Radiographs. J Contemp Dent Pract 2008; 9 (5):34-41.

DOI: 10.5005/jcdp-9-5-34

License: CC BY-NC 3.0

Published Online: 01-01-2010

Copyright Statement:  Copyright © 2008; The Author(s).


Abstract

Aim

The purpose of this study was to evaluate the effect of tube current reduction on image quality using medium and regular intensifying screens as well as a digital system for panoramic radiography.

Methods and Materials

A total of 150 panoramic images of 75 patients were obtained in the study. The initial images were taken at standard exposure settings, and secondary images were exposed with the tube current reduced at different rates.

Results

There was no statistically significant difference (p>0.05) between the two exposures for Group 3 (the rate of dose reduction 25%) while a statistically significant difference (p<0.05) was found in Group 4 (the rate of dose reduction 50%) using medium intensifying screens for all observers. No statistically significant difference was found between the two exposures on digital panoramic images.

Conclusion

According to the results of this study a dose reduction of 25% was achieved for medium intensifying screens and for digital panoramic images without any loss of image quality.

Clinical Significance

A substantial reduction in radiation exposure can be achieved in conventional panoramic radiography using a medium intensifying screen and in digital panoramic radiography without any loss of image quality needed for radiological evaluation of anatomical structures and pathological conditions.

Citation

Alkurt MT, Peker I, Usalan G, Altunkaynak B. Clinical Evaluation of Dose Reduction on Image Quality of Panoramic Radiographs. J Contemp Dent Pract 2008 July; (9)5:034-041.


PDF Share
  1. The effect of dose reduction on the detection of anatomical structures on panoramic radiographs. Dentomaxillofac Radiol 2006; 35(4):271-277.
  2. Radiation doses of commonly used dental radiographic surveys. Oral Surg Oral Med Oral Pathol 1994; 77(3):285-289.
  3. Extraoral and panoramic systems. Dent Clin North Am 2000; 44(2):257-272.
  4. Quality of film-based and digital panoramic radiography. Dentomaxillofac Radiol 2004; 33(1):32-36.
  5. Sens-A-Ray. A new system for direct digital intraoral radiography. Oral Surg Oral Med Oral Pathol 1992; 74(6):818-23.
  6. Kann die digitale Panoramaschichtröntgentechnik das filmbasierte Verfahren ersetzten? Zahnärztl Welt 1997; 106:510-514.
  7. Effects of dose reduction on the detectability of standardized radiolucent lesions in digital panoramic radiography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1998; 86(2):227-233.
  8. Effect of dose reduction in digital dental panoramic radiography on image quality. Dentomaxillofac Radiol 2002; 31(1):50-55.
  9. Organ doses and subjective image quality of indirect digital panoramic radiography. Dentomaxillofac Radiol 2001; 30(6):308-313.
  10. Human visual perception and ROC methodology in medical imaging. Phys Med Biol 1992; 37(1):1433-1476.
  11. Determination of the resolution of a digital system for panoramic radiography based on CCD technology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2004; 97(3):408-414.
  12. A comparison of the response of storage phosphor and film radiography to small variations in X-ray exposure. Dentomaxillofac Radiol 1997; 26(3):147-151.
  13. Dosimetry of digital panoramic imaging. Part I: patient exposure. Dentomaxillofac Radiol 2005;34(3):145-149.
PDF Share
PDF Share