The Journal of Contemporary Dental Practice

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 13 , ISSUE 6 ( November-December, 2012 ) > List of Articles

RESEARCH ARTICLE

A Comparative Evaluation of Curing Depth and Compressive Strength of Dental Composite Cured with Halogen Light Curing Unit and Blue Light Emitting Diode: An in vitro Study

R Divyashree, M Gururaj, CN Vijaya Kumar, Joseph Paul, L Krishnaprasada

Citation Information : Divyashree R, Gururaj M, Kumar CV, Paul J, Krishnaprasada L. A Comparative Evaluation of Curing Depth and Compressive Strength of Dental Composite Cured with Halogen Light Curing Unit and Blue Light Emitting Diode: An in vitro Study. J Contemp Dent Pract 2012; 13 (6):834-837.

DOI: 10.5005/jp-journals-10024-1238

Published Online: 01-04-2013

Copyright Statement:  Copyright © 2012; The Author(s).


Abstract

Purpose

To evaluate the curing depth and compressive strength of dental composite using halogen light curing unit and light emitting diode light curing unit.

Materials and methods

Eighty cylindrical composite specimens were prepared using posterior composite P60(3M). Forty specimens, out of which 20 samples (group A) cured with halogen light and 20 samples (group B) cured using light emitting diode (LED) light were checked for curing depth according to ISO 4049. Remaining 40 samples out of which 20 samples (group I) cured using halogen light and 20 samples (group II) cured using LED light were checked for compressive strength using Instron universal testing machine.

Results

Twenty samples (group A) cured with halogen light showed better curing depth than 20 samples (group B) cured with LED light. Twenty samples (group I) cured with halogen light showed almost similar results as 20 samples (group II) cured with LED light for compressive strength.

Conclusion

Halogen light commonly used to cure composite resin have greater depth of cure, when compared to LED light, while both the lights produced compressive strength which is almost similar.

Clinical significance

Lower depth of cure with the LED unit, compared to the QTH unit, is associated with different light scattering due to differences in spectral emission. LED technology differs from QTH by the spectral emission that favorably matches the absorption spectrum of camphorquinone.

How to cite this article

Kumar CNV, Gururaj M, Paul J, Krishnaprasada L, Divyashree R. A Comparative Evaluation of Curing Depth and Compressive Strength of Dental Composite cured with Halogen Light Curing Unit and Blue Light Emitting Diode: An in vitro Study. J Contemp Dent Pract 2012;13(6):834-837.


PDF Share
  1. Effectiveness of composite cure associated with different curing modes of LED lights. Operative Dentistry 2003;28-4:371-77.
  2. Restoration of fractured anterior teeth with ultraviolet light polymerized bonding materials; A new technique. J A Dent Assoc 1973;86:1349-54.
  3. In vitro depth of cure of photo-activated composites. J Dent Res 1982;61:1184-87.
  4. Chemistry of synthetic resins. Philip's science of dental materials (10th ed). Philadelphia: WB Saunders Co 1996:216.
  5. Visible light-cured and activating units. J Am Dent Assoc 1985;110:10-103.
  6. Advances in light curing. Am J Dent 2000;13:77D-81D.
  7. Light Emitting diode (LED) polymerization of dental composites; Flexural properties and polymerization potential. Biomaterials 2000;21:1379-85.
  8. Depth of cure and compressive strength of dental composites cured with blue light emitting diodes (LEDs) and halogen light. Dental materials 2000;16:41-47.
  9. Effect of light intensity and exposure duration on cure of resin composite. Operative Dentistry 1994;19:26-32.
  10. Degree of composite resin polymerization with visible light and argon laser. Am J Dent 1991;14:40-42.
  11. Effects of conventional high-intensity light curing on enamel shear bond strength of composite resin and resin-modified glass-ionomer. Am J Orthod Dentofacial Orthop 2001;119:30-35.
  12. Blue light emitting diodes—another method of light curing? British Dental Journal 1995 March 11: p.169.
  13. Dental composite depth of cure with halogen and blue light emitting diode technology. British Dental Journal 1999;1 & 6:388-91.
  14. Evaluating intensity output of lights in private dental offices. J Am Dent Assoc 1994 July;125:992-96.
  15. A Comparison of polymerization by light-emitting diode and halogen-based lightcuring units. J Am Dent Assoc 2003;133:335-41.
  16. Depth of cure and microleakage with high intensity and ramped resin-based composite curing lights. J Am Dent Assoc 2003;134:1215-23.
  17. Effect of curing tip diameter on the accuracy of dental radiometers. Operative Dentistry 1999;24:31-37.
  18. Evaluation of curing units used in private dental offices. Operative Dentistry 1998;23:50-54.
  19. The effectiveness of cure of LED and halogen curing lights at varying cavity depths. Operative dentistry 2003;28-6:707-15.
  20. Composite cure and shrinkage associated with high intensity curing light. Operative Dentistry 2003;28(4):357-64.
  21. Influence of light energy density on effectiveness of composite cure. Operative Dentistry 2002;26:460-66.
  22. Polymerization of composite resins: Argon laser vs conventional light. Operative Dentistry 1998;23:87-93.
  23. Thermal emission by different light-curing units. Operative Dentistry 2003;28(3):260-66.
  24. Light-emitting diode curing: Influence on selected properties of resin composites. Quintessence International 2002;34:71-75.
  25. Clinical guidelines for photo curing restorative resins. J Am Dent Assoc 1995 September;126:1280-86.
  26. Depth of cure of visible light cured resin: Clinical simulation. J Prosthetic Dent 1986 May;5: 574-78.
  27. Curing depth of a composite veneering material polymerized with seven different laboratory photo-curing units. J Oral Rehabilitation 1998;25:199-203.
  28. Curing depth of four composite veneering materials polymerized with different laboratory photo-curing units. Journal of Oral Rehabilitation 1998;25:348-52.
  29. Comparison of halogen, plasma and LED curing units. Operative Dentistry 2004;29(3):287-94.
  30. Surface hardness of light activated resin composites cured by two different visible-light sources: An in vitro study. Quintessence International 2001;32:401-05.
  31. Curing light intensity and depth of cure of resin-based composites tested according to international standards. J Am Dent Assoc 2002 April;133:429-34.
  32. Comparative efficiency of plasma and halogen light sources on composite micro-hardness in different curing conditions. Dental Materials 2003;19:493-500.
  33. Depth of cure and surface microhardness of composite resin cured with blue LED curing lights. Dental Materials 2004;20:364-69.
  34. Comparative depth of cure among various curing light types and methods. Operative Dentistry 2004;29:9-15.
  35. Composite conversion and temperature rise using a conventional, plasma arc, and an experimental blue LED curing unit. J Oral Rehabilitation 2002 July;7(29):662.
  36. Comparison of quartz-tungsten-halogen, light emitting diode, and plasma arc curing lights. J Adhes Dent 2003;5(3):193-207.
  37. Relationship between shade and depth of cure for light activated dental composite resins. Dental Materials 1986;2:80-84.
  38. Some factors influencing the depth of cure of visible light activated composite resins. Aus Dent J 1990;35(3):213-18.
  39. Kim CW. Degree of polymerization of resin composites by different light sources. J Oral Rehabilitation 2002;29(12)1165-73.
  40. Comparison of composite curing parameters: Effects of light source and curing mode on conversion, temperature rise and polymerization shrinkage. Operative Dentistry 2006;31(2):219-26.
  41. Curing capability of halogen and led light curing units in deep class II cavities in extracted human molars. Operative Dentistry 2006;31(3):354-63.
  42. Effect of light-curing units and activation mode on polymerization shrinkage and shrinkage stress of composite resins. J Appl Oral Sci 2008;16(1):35-42.
  43. Comparison of depth of cure, Hardness and heat generation of LED and high intensity QTH light sources. Eur J Dent 2011;5:299-304.
  44. Curing effectiveness of resin composites at different exposure times using LED and halogen units. Med Oral Patol Oral Cir Bucal 2009 Jan 1;14(1):E51-56.
  45. Effect of different photo-initiators and light curing units on degree of conversion of composites. Braz Oral Res 2010 Jul-Sep;24(3):263-70.
PDF Share