The Journal of Contemporary Dental Practice

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 14 , ISSUE 4 ( July-August, 2013 ) > List of Articles

RESEARCH ARTICLE

Comparison of Dimensional Accuracy of Four Different Die Materials before and after Disinfection of the Impression: An in vitro Study

Yamini Nandini, KB Vinitha

Citation Information : Nandini Y, Vinitha K. Comparison of Dimensional Accuracy of Four Different Die Materials before and after Disinfection of the Impression: An in vitro Study. J Contemp Dent Pract 2013; 14 (4):668-674.

DOI: 10.5005/jp-journals-10024-1383

Published Online: 01-12-2013

Copyright Statement:  Copyright © 2013; The Author(s).


Abstract

Background

This study was conducted to compare the linear dimensional accuracy of die materials before and after disinfection of the impression. Type IV and V conventional dental stone, type IV-resin impregnated and copper-plated die materials were studied.

Materials and methods

A stainless-steel master die analogs to a complete veneer crown preparation with three scribed lines (I: vertical, II and III: horizontal) was machined and measurements were made from these scribed reference lines. Impressions were made with monophase addition silicone impression material for each of the specimens. 2% glutaraldehyde was used as a disinfectant. The fabricated dies were measured to the nearest 0.0001 mm. ANOVA and post hoc was carried out using Scheffe multiple comparison test at significance level of 0.05.

Results

Type IV resin-impregnated dental stone and copperplated dies approximated the dimensions of the master die. Type IV and V conventional dental stone dies showed greater variation in measurements. Statistically significant differences were observed for type IV resin-impregnated and copper-plated dies in dimension I and III. For dimension II no significant differences were found for dies fabricated from four die materials. A one-way analysis of variance indicated no statistical significant differences among the two groups of dies fabricated from disinfectant treated impressions and those fabricated from nondisinfectant treated impressions.

Conclusion

Type IV resin-impregnated dental stone and copper-plated dies are dimensionally more accurate than type IV and V conventional dental stone die materials. No significant linear distortion in the dies fabricated from the disinfected impressions was observed.

How to cite this article

Nandini Y, Vinitha KB, Manvi S, Smitha M. Comparison of Dimensional Accuracy of Four Different Die Materials before and after Disinfection of the Impression: An in vitro Study. J Contemp Dent Pract 2013;14(4):668-674.


PDF Share
  1. Determination of the accuracy of three die systems. J Prosthet Dent 1991;65:758-762.
  2. Detail reproduction, contact angles and die hardness of elastomeric impression and gypsum die material combinations. Int J Prosthodont 2000;13:214-220.
  3. Dimensional accuracy of 7 die materials. J Prosthet Dent 2005;14:25-31.
  4. Disinfection of impression materials to prevent viral cross contamination: a review and a protocol. Int J Prosthodont 1993;6:480-494.
  5. The accuracy and efficacy of disinfection by spray atomization on elastomeric impressions. J Prosthet Dent 1989;62:468-475.
  6. Influence of disinfectants on polyvinylsiloxane impression material. J Dent Res 1987;66:133.
  7. The dimensional accuracy of improved dental stone, silver plated and epoxy resin die materials. J Prosthet Dent 1988;59:307-310.
  8. Impression materials. In: Restorative dental materials. 10th ed. Mosby 1997;281-332.
  9. Properties of die materials: a comparative study. J Prosthet Dent 1966;16:119.
  10. Die materials for inlay, crown and bridge work. Br Dent J 1969;115:415.
  11. Dimensional accuracy of improved dental stone and epoxy resin die materials. Part I: single die. J Prosthet Dent 1997;77:131-135.
  12. Impression materials and electrodeposits. Part I: Impression materials. J Prosthet Dent 1981;45:44-48.
  13. Andres. Study of the physical properties of type IV gypsum, resin-containing, and epoxy die materials. J Prosthet Dent 2000;83:466-473.
  14. Effect of three variables on the accuracy and variability of electroplated copper dies. Int J Prosthodont 1996;9:547-554.
  15. The effect of immersion disinfection of elastomeric impressions on the surface detail reproduction of improved gypsum casts. J Prosthet Dent 1990; 63:233-241.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.