ORIGINAL RESEARCH

Shaping Ability of Two-shape and ProTaper Gold Files by using Cone-beam Computed Tomography

Shalini Singh, Tarun Gupta, Vinisha Pandey, Harshit Singhania, Pooja Pandey, Shweta Gangavane

Keywords : Apical transportation, Centering ratio, M-wire- ProTaper gold, T-wire-two-shape, Volume of removed dentin

Citation Information : Singh S, Gupta T, Pandey V, Singhania H, Pandey P, Gangavane S. Shaping Ability of Two-shape and ProTaper Gold Files by using Cone-beam Computed Tomography. J Contemp Dent Pract 2019; 20 (3):330-334.

DOI: 10.5005/jp-journals-10024-2518

License: CC BY-NC 4.0

Published Online: 01-04-2019

Copyright Statement:  Copyright © 2019; The Author(s).


Abstract

Aim: T-Wire and rotating motion of two-shape (2S), M-wire and rotating motion of ProTaper Gold (PG) are the recent innovations of Nickle Titanium (NiTi) rotary file system by means of thermal treatment. Therefore, a study was planned to assess the shaping ability of 2 Shape and ProTaper Gold using cone beam computed tomography (CBCT) Materials and methods: Thirty freshly extracted mandibular first molars were selected, and Pre-instrumentation CBCT imaging was performed to attain mesial and distal dentin wall measurements followed by chemo-mechanical preparation using the following NiTi files: 2S and ProTaper Gold. Post instrumentation CBCT imaging was performed for evaluation of the volume of removed dentin, apical transportation, and centering ratio. Statistical analysis was confirmed by a suitable analysis test with significance set at 0.05r. Results: In terms of the total volume of removed dentin, apical transportation, and centering ratio there was a significant difference noted between the tow-shape and ProTaper Gold. 2Shape performed better in all aspects compared to ProTaper Gold. Conclusion: Two-shape (2S) maintained better original canal anatomy and volume of removed dentin was also less during chemo-mechanical preparation when compared to ProTaper Gold. Clinical significance: Two-shape (2S) system when used clinically in patients may perform better and produce less canal transportation and canal preparation will be more centered as compared to the ProTaper Gold system.


PDF Share
  1. Sahu GK, Shivani C, Nandkishore KJ, et al. Rotary endodontics or reciprocating endodontics: Which is new and which is true? J Health Sci Res 2016;7:51.57.
  2. Krishan S, Aggarwal A, Singh K. Endodontic Rotary Systems. A Review. J Adv Med Dent Sci Res 2016;4:84.88.
  3. Arora V, Yadav MP, Singh SP, et al. Comparative evaluation of post obturation materials on reinforcement of Peri. Cervical Dentin (PCD).An In vitro Study. IJTEEE 2015;3:39.43.
  4. Grande NM, Plotino G, Lavorgna L, et al. Influence of different root canal.filling materials on the mechanical properties of root canal dentin. J Endod 2007;33:859.863.
  5. Micro Mega, France. 2 Shape. Available from: http://micromega. com/shaping/2shape?lang=en
  6. Amr M E, Shaymaa E E. 2016. Shaping abilty of ProTaper Gold and ProTaper Universal files by using cone beam computed tomography. Ind. Dent. J. Res., 27:37-41.
  7. Rodig T, Hulsmann M, Kahlmeier C. Comparison of root canal preparation with two rotary NiTi instruments: ProFile. 04 and GT rotary. Int Endod J 2007;40:553.562.
  8. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am 1974;18:269.296.
  9. Hashem AA, Ghoneim AG, Lutfy RA, et al. 2012. Geometric analysis of root canals prepared by four rotary NiTi shaping systems. J. Endod., 38:996-1000.
  10. Berutti E, Paolino DS, Chiandussi G, et al. Root canal anatomy preservation of WaveOne reciprocating files with or without glide path. J Endod 2012;38:101-104.
  11. Merrett SJ, Bryant ST, Dummer PM. Comparison of the shaping ability of RaCe and FlexMaster rotary nickel-titanium systems in simulated canals. J Endod 2006;32:960-962.
  12. Loizides AL, Kakavetsos VD, Tzanetakis GN, et al. A comparative study of the effects of two nickel-titanium preparation techniques on root canal geometry assessed by microcomputed tomography. J Endod 2007;33:1455-1459.
  13. Jafarzadeh H, Abbott PV. Ledge formation: Review of a great challenge in endodontics. J Endod 2007;33:1155-62
  14. Schneider SW. A comparison of canal preparations in straight and curved root canals. Oral Surg Oral Med Oral Pathol 1971;32:271-275.
  15. Hartmann MS, Barletta FB, Camargo Fontanella VR, et al. Canal transportation after root canal instrumentation: A comparative study with computed tomography. J Endod 2007;33:962-965.
  16. Zanette F, Grazziotin-Soares R, Flores ME, Camargo Fontanella VR, Gavini G, Barletta FB. Apical root canal transportation and remaining dentin thickness associated with ProTaper Universal with and without PathFile. J Endod 2014;40:688-693.
  17. Hashem AA, Ghoneim AG, Lutfy RA, et al. Geometric analysis of root canals prepared by four rotary NiTi shaping systems. J Endod 2012;38:996-1000.
  18. Michetti J, Maret D, Mallet JP, et al. Validation of cone beam computed tomography as a tool to explore root canal anatomy. J Endod 2010;36:1187-1190.
  19. Elnaghy AM, Elsaka SE. Evaluation of root canal transportation, centering ratio, and remaining dentin thickness associated with ProTaper next instruments with and without glide path. J Endod 2014;40:2053.2056.
  20. Zanette F, Grazziotin-Soares R, Flores ME, et al. Apical root canal transportation and remaining dentin thickness associated with ProTaper Universal with and without Path File. J Endod 2014;40: 688-693.
  21. Shivashankar MB, Niranjan NT, Jayasheel A, et al. Computed tomography evaluation of canal transportation and volumetric changes in root canal dentin of curved canals using Mtwo, ProTaper and ProTaper next rotary system.an in.vitro study. J Clin Diagn Res 2016;10:ZC10.4.
  22. Arias A, Vasconcelos R, Hernandez A, et al. Torsional Performance of ProTaper Gold Rotary Instruments during Shaping of Small Root Canals after 2 Different Glide Path Preparations. J Endod 2017;43(3):447-451.
  23. Bayram M, Bayram E, Ocak M, et al. Effect of ProTaper Gold, Self-Adjusting File, and XP-endo Shaper Instruments on Dentinal Microcrack Formation: A Micro.computed Tomographic Study. J Endod 2017;43(7):1166-1169.
  24. Arslan H, Yildiz E, Gunduz H, et al. Comparative study of ProTaper gold, reciproc, and ProTaper universal for root canal preparation in severely curved root canals. J Conserv Dent 2017;20(4):222-224.
  25. Abdulrahman A, Mohammad A, Shibu T, et al. Shaping ability of ProTaper gold and WaveOne gold nickel-titanium rotary file in different canal configurations. Saudi Endod J 2018;8(3):202-207.
  26. Saber Sel D, Abu El Sadat SM. Effect of altering the reciprocation range on the fatigue life and the shaping ability of WaveOne nickel-titanium instruments. J Endod 2013;39:685-688.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.