The Journal of Contemporary Dental Practice

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 22 , ISSUE 11 ( November, 2021 ) > List of Articles

REVIEW ARTICLE

Clinical and Biomechanical Performance of Occlusal Veneers: A Scoping Review

LuisGabriel Ladino, Martin Eduardo Sanjuan, Darell Josué Valdéz, Rosa Angélica Eslava

Keywords : CAD/CAM, Dental ceramics, Fracture resistance, Occlusal veneer, Tooth wear

Citation Information : Ladino L, Sanjuan ME, Valdéz DJ, Eslava RA. Clinical and Biomechanical Performance of Occlusal Veneers: A Scoping Review. J Contemp Dent Pract 2021; 22 (11):1327-1337.

DOI: 10.5005/jp-journals-10024-3226

License: CC BY-NC 4.0

Published Online: 24-02-2022

Copyright Statement:  Copyright © 2021; The Author(s).


Abstract

Aim: This manuscript aims to evaluate, through a scoping review, current knowledge of the biomechanical behavior, materials, preparations, and limitations of occlusal veneers. Background: Occlusal veneers are a minimally invasive alternative for the additive restoration of posterior teeth with significant loss of the occlusal structure. This type of restoration has been emerged in recent years as an alternative to invasive treatment, which in the same way seeks to restore the structure of the posterior teeth. All this is because in recent years restorative dentistry has focused a large part of its objectives on conservative therapies. Review results: Five electronic databases—PubMed, Cochrane, LILACS, EMBASE, and Google Scholar—were searched. Title and abstracts were independently screened by three reviewers, followed by a full-text review. A total of 42 articles met our inclusion criteria; most of these studies were in vitro (n = 35) and other studies were clinical studies (n = 7). These in vitro studies included 21 studies that analyzed the type of preparation and 6 studies that evaluated the limitations of occlusal veneers. Conclusion: Thicknesses between 0.7 and 1.0 mm are recommended for ceramic materials; in addition, thicknesses less than 0.7 mm are recommended to use polymeric materials. The materials used for this type of restoration are plastic- and ceramic-based materials, whose load resistance values were found to exceed 2000 N in most studies. It is recommended to carry out a minimally invasive preparation or not to carry out a dental preparation, as long as there is a peripheral enamel to make an external bevel that redirects the eccentric forces to the axis of the tooth. Clinical significance: Restorative dentistry has moved toward conservative treatments with the least amount of dental tissue being removed. Occlusal veneers appear to be a conservative option in the reconstruction of tooth tissues lost due to tooth wear and in cases where it is necessary to restore or increase the vertical dimension.


HTML PDF Share
  1. Abrahamsen TC. The worn dentition—pathognomonic patterns of abrasion and erosion. Int Dent J 2005;55(4):268–276. DOI: 10.1111/j.1875-595x.2005.tb00064.x.
  2. Murdoch-Kinch CA, McLean ME. Minimally invasive dentistry. J Am Dent Assoc 2003;134(1):87–95. DOI: 10.14219/jada.archive.2003.0021.
  3. Kim Li RW, Chow TW, Matinlinna JP. Ceramic dental biomaterials and CAD/CAM technology: State of the art. J Prosthodont Res 2014;58(4):208–216. DOI: 10.1016/j.jpor.2014.07.003.
  4. Ferracane JL. Resin composite – state of the art. Dent Mater 2011;27(1):29–38. DOI: 10.1016/j.dental.2010.10.020.
  5. Van Meerbeek B, De Munck J, Yoshida Y, et al. Buonocore memorial lecture. Adhesion to enamel and dentin: current status and future challenges. Oper Dent 2003;28(3):215–235. PMID: 12760693.
  6. Schlichting LH, Maia HP, Baratieri LN, et al. Novel-design ultra-thin CAD/CAM composite resin and ceramic occlusal veneers for the treatment of severe dental erosion. J Prosthet Dent 2011;105(4):217–226. DOI: 10.1016/S0022-3913(11)60035-8.
  7. Magne P, Stanley K, Schlichting LH. Modeling of ultrathin occlusal veneers. Dent Mater 2012;28(7):777–782. DOI: 10.1016/j.dental.2012.04.002.
  8. Schlichting LH, Resende TH, Reis KR, et al. Simplified treatment of severe dental erosion with ultrathin CAD/CAM composite occlusal veneers and anterior bilaminar veneers. J Prosthet Dent 2016;116(4):474–482. DOI: 10.1016/j.prosdent.2016.02.013.
  9. Yazigi C, Kern M, Chaar MS. Influence of various bonding techniques on the fracture strength of thin CAD/CAM-fabricated occlusal glass-ceramic veneers. J Mech Behav Biomed Mater 2017;75:504–511. DOI: 10.1016/j.jmbbm.2017.08.016.
  10. Kim JH, Cho BH, Lee JH, et al. Influence of preparation design on fit and ceramic thickness of CEREC 3 partial ceramic crowns after cementation. Acta Odontol Scand 2015;73(2):107–113. DOI: 10.3109/00016357.2014.956145.
  11. Politano G, Van Meerbeek B, Peumans M. Nonretentive bonded ceramic partial crowns: concept and simplified protocol for long-lasting dental restorations. J Adhes Dent 2018;20(6):495–510. DOI: 10.3290/j.jad.a41630.
  12. Abd AS, Mohsen CA, Ramzy MI. Fracture strength of two types of posterior occlusal veneers made of hybrid ceramics with different thicknesses. Indian J Public Heal Res Dev 2020;11(4):913–919. DOI: 10.21275/ART2019417.
  13. Emam Z, Aleem NA. Influence of different materials and preparation designs on marginal adaptation and fracture resistance of CAD/CAM fabricated occlusal veneers. Egypt Dent J 2020;66(1):439–452. DOI: 10.21608/edj.2020.79120.
  14. Saber Rabeae H, Adel Mohsen C, Waaz Amgad S. Assessment of fracture force of CAD/CAM fabricated occlusal veneer restorations with different thicknesses. Indian J Public Heal Res Dev 2020;11(1):1131. DOI: 10.37506/v11/i1/2020/ijphrd/193991.
  15. Falahchai M, Babaee Hemmati Y, Neshandar Asli H, et al. Effect of tooth preparation design on fracture resistance of zirconia-reinforced lithium silicate overlays. J Prosthodont 2020;29(7):617–622. DOI: 10.1111/jopr.13160.
  16. Falahchai M, Babaee Hemmati Y, Neshandar Asli H, et al. Marginal adaptation of zirconia-reinforced lithium silicate overlays with different preparation designs. J Esthet Restor Dent 2020;32(8):823–830. DOI: 10.1111/jerd.12642.
  17. Heck K, Paterno H, Lederer A, et al. Fatigue resistance of ultrathin CAD/CAM ceramic and nanoceramic composite occlusal veneers. Dent Mater 2019;35(10):1370–1377. DOI: 10.1016/j.dental.2019.07.006.
  18. Al-Akhali M, Kern M, Elsayed A, et al. Influence of thermomechanical fatigue on the fracture strength of CAD/CAM-fabricated occlusal veneers. J Prosthet Dent 2019;121(4):644–650. DOI: 10.1016/j.prosdent.2018.07.019.
  19. Krummel A, Garling A, Sasse M, et al. Influence of bonding surface and bonding methods on the fracture resistance and survival rate of full-coverage occlusal veneers made from lithium disilicate ceramic after cyclic loading. Dent Mater 2019;35(10):1351–1359. DOI: 10.1016/j.dental.2019.07.001.
  20. Maeder M, Pasic P, Ender A, et al. Load-bearing capacities of ultra-thin occlusal veneers bonded to dentin. J Mech Behav Biomed Mater 2019;95(1):165–171. DOI: 10.1016/j.jmbbm.2019.04.006.
  21. Al-Akhali M. Influence of adhesive technique and thermomechanical fatigue on the fracture strength of minimally invasive CAD/CAM occlusal veneers [Doctoral dissertation]. Universitätsbibliothek Kiel; 2019.
  22. Yazigi C. Influence of dentin bonding techniques on the fracture strength and fracture mode of thin occlusal glass-ceramic veneers dissertation [Doctoral dissertation]. Christian-Albrechts Universität Kiel; 2019.
  23. Edgerley PD, Versluis A, Tantbirojn D, et al. Impact of overdried preparation and thermocycling on the fracture of CAD/CAM hybrid ceramic occlusal veneer restorations. Int J Prosthodont Restor Dent 2019;9(2):38–42. DOI: 10.5005/jp-journals-10019-1231.
  24. Perez P, Benitez D, Vergel J. Effect of the thickness of two ceramic materials on resistance to fracture for the fabrication of occlusal veneers. J Chem Inf Model 2018;53(9):1689–1699.
  25. Cardenas-Sallhue H, Delgadillo-Avila J, Alvarado-Menacho S. Functional Aesthetic Rehabilitation of a Patient with Dental Biocorrosion: A Case Report. Chin J Dent Res 2020;23(3):215–220. DOI: 10.3290/j.cjdr.a45226.
  26. Risco J, Alvarez E. Marginal microfiltration in table top ceromer inlays cemented with resinous cements: self-etching, universal and thermoplastic resin. 2019;21:67–85.
  27. Ascanio M, Camargo C, Maldonado MT. In vitro comparison of the resistance to fracture against compressive forces, between a restoration in lithium silicate reinforced with zirconium cemented on enamel and enamel-dentin in premolar teeth. 2019;1(8):117–125. Available from: https://repository.usta.edu.co/handle/11634/21343?show=full
  28. Baldissara P, Monaco C, Onofri E, Fonseca RG, Ciocca L. Fatigue resistance of monolithic lithium disilicate occlusal veneers: a pilot study. Odontology 2019;107(4):482–490. DOI: 10.1007/s10266-019-00417-7.
  29. Andrade JP, Stona D, Bittencourt HR, et al. Effect of different computer-aided design/computer-aided manufacturing CAD/CAM materials and thicknesses on the fracture resistance of occlusal veneers. Oper Dent 2018;43(5):539–548. DOI: 10.2341/17-131-L.
  30. Resende T, Reis K, Schlichting L, et al. Ultrathin CAD/CAM ceramic occlusal veneers and anterior bilaminar veneers for the treatment of moderate dental biocorrosion: a 1.5-year follow-up. Oper Dent 2018;43(4):337–346. DOI: 10.2341/17-007-T.
  31. Aqlan S, Kheiralla L. Fracture resistance of thin occlusal veneers made from hybrid ceramic (Cerasmart) – in vitro study. Al-Azhar J Dent Sci 2018;21(3):293–297. DOI: 10.21608/AJDSM.2018.71575.
  32. Abdelhameed AM, Abd-El Aziz MH, Hamza TA. In vitro study to evaluate the effect of different material types and preparation designs on the fracture resistance of occlusal veneers. Al-Azhar J Dent Sci 2018;21(1):65–71. DOI: 10.21608/AJDSM.2020.71477.
  33. Singh I, Shetty R, Mehta D, et al. Prefabricated laser sintered composite veneers and occlusal vertical dimensions: case reports. J Contemp Dent Pract 2018;19(11):1418–1424. PMID: 30602651.
  34. Magne P, Schlichting LH, Maia HP, et al. In vitro fatigue resistance of CAD/CAM composite resin and ceramic posterior occlusal veneers. J Prosthet Dent 2010;104(3):149–157. DOI: 10.1016/S0022-3913(10)60111-4.
  35. Bahillo J, Jané L, Bortolotto T, et al. Full-mouth composite rehabilitation of a mixed erosion and attrition patient: a case report with V-shaped veneers and ultra-thin CAD/CAM composite overlays. Quintessence Int (Berl) 2014;45(9):749–756. DOI: 10.3290/j.qi.a32439.
  36. Johnson AC, Versluis A, Tantbirojn D, et al. Fracture strength of CAD/CAM composite and composite-ceramic occlusal veneers. J Prosthodont Res 2014;58(2):107–114. DOI: 10.1016/j.jpor.2014.01.001.
  37. Egbert JS, Johnson AC, Tantbirojn D, et al. Fracture strength of ultrathin occlusal veneer restorations made from CAD/CAM composite or hybrid ceramic materials. Oral Sci Int 2015;12(2):53–58. DOI: 10.1016/S1348-8643(15)00017-8.
  38. Sasse M, Krummel A, Klosa K, et al. Influence of restoration thickness and dental bonding surface on the fracture resistance of full-coverage occlusal veneers made from lithium disilicate ceramic. Dent Mater 2015;31(8):907–915. DOI: 10.1016/j.dental.2015.04.017.
  39. Al-Akhali M, Chaar MS, Elsayed A, et al. Fracture resistance of ceramic and polymer-based occlusal veneer restorations. J Mech Behav Biomed Mater 2017;74:245–250. DOI: 10.1016/j.jmbbm.2017. 06.013.
  40. Llompart J, López AI. Marginal microfiltration of ceromeric occlusal veneers with different endings. An in vitro study. Rev Científica Odontológica 2018;06(1):9–18.
  41. Abu-Izze FO, Ramos GF, Borges ALS, Anami LC, Bottino MA. Fatigue behavior of ultrafine tabletop ceramic restorations. Dent Mater 2018;34(9):1401–1409. DOI: 10.1016/j.dental.2018.06.017.
  42. Ioannidis A, Bomze D, Hämmerle CHF, et al. Load-bearing capacity of CAD/CAM 3D-printed zirconia, CAD/CAM milled zirconia, and heat-pressed lithium disilicate ultra-thin occlusal veneers on molars. Dent Mater 2020;36(4):109–116. DOI: 10.1016/j.dental.2020.01.016.
  43. Albelasy EH, Hamama HH, Tsoi JKH, et al. Fracture resistance of CAD/CAM occlusal veneers: a systematic review of laboratory studies. J Mech Behav Biomed Mater 2020;110:103948. DOI: 10.1016/j.jmbbm.2020.103948.
  44. Angerame D, De Biasi M, Agostinetto M, et al. Influence of preparation designs on marginal adaptation and failure load of full-coverage occlusal veneers after thermomechanical aging simulation. J Esthet Restor Dent 2019;31(3):280–289. DOI: 10.1111/jerd.12457.
  45. Huang X, Zou L, Yao R, et al. Effect of preparation design on the fracture behavior of ceramic occlusal veneers in maxillary premolars. J Dent 2020;97:103346. DOI: 10.1016/j.jdent.2020.103346.
  46. Zhang H, Lv P, Du W, et al. Comparison of fracture load and surface wear of microhybrid composite and ceramic occlusal veneers. J Prosthodont 2020;29(5):387–393. DOI: 10.1111/jopr.13156.
  47. Ferrando-Cascales Á, Astudillo-Rubio D, Pascual-Moscardó A, et al. A facially driven complete-mouth rehabilitation with ultrathin CAD-CAM composite resin veneers for a patient with severe tooth wear: a minimally invasive approach. J Prosthet Dent 2020;123(4): 537–547. DOI: 10.1016/j.prosdent.2019.04.011.
  48. Hassan M, Moustafa M. Synergy between the components of the restorative complex. Influence of the preparation design and aging on the vertical marginal gap of occlusal veneers constructed of different ceramic materials. Egypt Dent J 2020;66(2):1261–1274. DOI: 10.21608/edj.2020.28045.1108.
  49. Abbas R, Mandour M, Hasan S. Effect of material type and thickness on fatigue resistance of posterior bonded occlusal veneers. Al-Azhar Dent J Girls 2020;7(2):171–178. DOI: 10.21608/adjg.2020.7842.1111.
  50. Ioannidis A, Mühlemanna S, Özcana M, et al. Ultra-thin occlusal veneers bonded to enamel and made of ceramic or hybrid materials exhibit load-bearing capacities not different from conventional restorations. J Mech Behav Biomed Mater 2018;90(8):433–440. DOI: 10.1016/j.jmbbm.2018.09.041.
  51. Lauvahutanon S, Takahashi H, Shiozawa M, et al. Mechanical properties of composite resin blocks for CAD/CAM. Dent Mater J 2014;33(5):705–710. DOI: 10.4012/dmj.2014-208.
  52. Bakeman EM, Rego N, Chaiyabutr Y, et al. Influence of ceramic thickness and ceramic materials on fracture resistance of posterior partial coverage restorations. Oper Dent 2015;40(2):211–217. DOI: 10.2341/12-459-L.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.