Influence of T-scan System on Occlusion Correction of Implant Supported Prostheses: A Systematic Review

Anupama Aradya, Raghavendra Swamy Koodalakuppe Nagarajagowda, Ravi Maraballi Basavaraju, Sowmya Srinivas, Sindhu Sudhakar Kumararama

Keywords : Dental implants, Occlusion, Restorations, T-scan

Citation Information : Aradya A, Nagarajagowda RS, Basavaraju RM, Srinivas S, Kumararama SS. Influence of T-scan System on Occlusion Correction of Implant Supported Prostheses: A Systematic Review. J Contemp Dent Pract 2022; 23 (1):105-117.

DOI: 10.5005/jp-journals-10024-3288

License: CC BY-NC 4.0

Published Online: 21-05-2022

Copyright Statement:  Copyright © 2022; The Author(s).


Abstract

Aim: To systematically evaluate the literature evidence regarding the suitability of the T-scan occlusal system for implant supported prostheses. Materials and methods: A thorough bibliographic search was conducted on PubMed, Google Scholar, Cochrane library, Web of Science, EMBASE, and Scopus to collect relevant articles published from January 1, 2008 to August 30, 2021, using a combination of the following words: “T-scan,” “Implant supported prostheses,” and “dental implant” according to the PRISMA guidelines for the focused research question constructed using the PICO criteria. Randomized control trials, prospective studies, retrospective studies on the use of T-scan system in implant-supported prostheses reported in English language were included in the study. Results: This review consisted of 17 studies and 359 patients rehabilitated with 1,126 implants. In 3 studies, removable types of prostheses were given over implants, and in 14 studies, fixed types of prostheses were given. Nine studies determined the percentage of occlusal force magnitude and occlusion time sequence. Three studies measured the localization of the occlusion center. T-scan was used in two studies to measure the amount of gingival crevicular fluid after occlusal adjustment. The follow-up period ranged from 6 months to 2 years or more. Conclusion: T-scan proved with better results than other occlusal analysis indicators in terms of occlusion measurement, clinical execution, quantify the location and contact timing, and occlusion in 3D with more precision. Clinical significance: T-scan occlusal analysis system is widely used in dentistry and there is an increase in the number of studies, so a systematic review evaluating and comparing results is warranted.


HTML PDF Share
  1. Aradya A, Dhakshaini MR, Nitin VM, et al. T-Scan–dawn of a new quantitative occlusal analyser in dentistry. Int J Pharm Res 2021;13(2):4337–4345. DOI: 10.31838/ijpr/2021.13.02.520.
  2. Gross MD. Occlusion in implant dentistry. A review of the literature of prosthetic determinants and current concepts. Aust Dent J 2008; 53(1 Suppl):S60–S68. DOI: 10.1111/j.1834-7819.2008.00043.x.
  3. Sheridan RA, Decker AM, Plonka AB, et al. The role of occlusion in implant therapy: a comprehensive updated review. Implant Dent 2016;25(06):829–838. DOI: 10.1097/ID.0000000000000488.
  4. Froum SJ. Dental implant complications: etiology, prevention and treatment, 2nd ed. John Wiley and Sons, New Jersey 2016.
  5. Moher D, Shamseer L, Clarke M, et al. Preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) 2015 statement. Syst Rev 2015;4(1):1. DOI: 10.1186/2046-4053-4-1.
  6. Higgins JP, Green S. Cochrane handbook for systematic reviews of interventions 4.2.6. In: Cochrane Library 2016; 2006. p. 4.
  7. Wells GA, Shea B, O'Connell D, et al. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomized studies in meta-analysis. Available from: http://www.ohri.ca/programs/clinical_epidemiology/oxford.asp [Last accessed on April 25, 2016].
  8. Luo Q, Ding Q, Zhang L, et al. Analyzing the occlusion variation of single posterior implant-supported fixed prostheses by using the T-Scan system: a prospective 3-year follow-up study. J Prosthet Dent 2020;123(1):79–84. DOI: 10.1016/j.prosdent.2018.12.012.
  9. Madani AS, Nakhaei M, Alami M, et al. Postinsertion posterior single-implant occlusion changes at different intervals: a T-Scan computerized occlusal analysis. J Contemp Dent Pract 2017;18: 927–932. DOI: 10.5005/jp-journals-10024-2151.
  10. Viña-Almunia J, Pellicer-Chover H, García-Mira B, et al. Influence of occlusal loading on peri-implant inflammatory cytokines in crevicular fluid: a prospective longitudinal study. Int J Implant Dent 2020;6(1):71. DOI: 10.1186/s40729-020-00262-2.
  11. Yu W, Chen S, Li X, et al. Evaluation of 1-Piece versus 3-piece framework designs for the edentulous mandible with fixed implant-supported prostheses: a clinical, occlusal and biomechanical study. J Prosthodont 2021;30(4):290–297. DOI: 10.1111/jopr.13320.
  12. Kabbua P, Aunmeungtong W, Khongkhunthian P. Computerised occlusal analysis of mini-dental implant-retained mandibular overdentures: a 1-year prospective clinical study. J Oral Rehabil 2020;47:757–765. DOI: 10.1111/joor.12969.
  13. Ma FF, Lin Y, Di P, et al. All-on-4 occlusion study: using T-Scan III occlusal analysis system. Chin J Stomatol 2016;51(9):517–520. DOI: 10.3760/cma.j.issn.1002-0098.2016.09.002.
  14. Barrio PP, Ribas LK, Lastra BR, et al. Variation in dental occlusal schemes two years after placement of single-implant posterior crowns. A preliminary study. J Oral Implantol 2021. DOI: 10.1563/aaid-joi-D-19-00239.
  15. Khuder T, Yunus N, Sulaiman E, et al. Association between occlusal force distribution in implant overdenture prostheses and residual ridge resorption. J Oral Rehabil 2017;44(5):398–404. DOI: 10.1111/joor.12504.
  16. Roque MA, Gallucci GO, Lee SJ. Occlusal pressure redistribution with single implant restorations. J Prosthodont 2017;26(4):275–279. DOI: 10.1111/jopr.12552.
  17. Yu W, Li X, Ma L, et al. Gnathology in implant-supported fixed restoration in edentulous mandible. West Chin J Stomatol 2020;38(1):30–36. DOI: 10.7518/hxkq.2020.01.006.
  18. Yi-Fang H, Shih-Ping L, Chih-Hsin M, et al. Prosthetic design related to peri-implant bone resorption in microvascular free fibular flap among patients with oral cancer: a retrospective clinical study. J Prosthet Dent 2020;124(3):395–399. DOI: 10.1016/j.prosdent.2019.07.019.
  19. Liu CW, Chang YM, Shen YF, et al. Using the T-Scan III system to analyse occlusal function in mandibular reconstruction patients: a pilot study. Biomed J 2015;38(1):52–57. DOI: 10.4103/2319-4170.128722.
  20. Pellicer-Chover H, Viña-Almunia J, Romero-Millán J, et al. Influence of occlusal loading on peri-implant clinical parameters. A pilot study. Med Oral Patol Oral Cir Bucal 2014;19(3):e302–e307. DOI: 10.4317/medoral.19477.
  21. Zhou T, Wongpairojpanich J, Sareethammanuwat M, et al. Digital occlusal analysis of pre and post single posterior implant restoration delivery: a pilot study. PLoS One 2021;16(7):e0252191. DOI: 10.1371/journal.pone.0252191.
  22. Ohkubo C, Kobayashi M, Suzuki Y, et al. Effect of implant support on distal-extension removable partial dentures: in vivo assessment. Int J Oral Maxillofac Implants 2008;23(6):1095–1101. PMID: 19216279.
  23. Buduru S, Mesaros A, Talmaceanu D, et al. Occlusion in the digital era: a report on 3 cases. Med Pharm Rep 2019;92(Suppl No 3):S78–S84. DOI: 10.15386/mpr-1524.
  24. Cotruţă AM, Mihăescu CS, Tănăsescu LA, et al. Analyzing the morphology and intensity of occlusal contacts in implant-prosthetic restorations using T-Scan system. Rom J Morphol Embryol 2015;56(1):277–281. PMID: 25826517.
  25. Bozhkova TP. The T-SCAN system in evaluating occlusal contacts. Folia Med 2016;58(2);122–130. DOI: 10.1515/folmed-2016-0015.
  26. Agbaje JO, Casteele EV, Salem AS, et al. Assessment of occlusion with the T-Scan system in patients undergoing orthognathic surgery. Sci Rep 2017;7(1):5356. DOI: 10.1038/s41598-017-05788-x.
  27. Majithia IP, Arora V, Anil Kumar S, et al. Comparison of articulating paper markings and T-Scan III recordings to evaluate occlusal force in normal and rehabilitated maxillofacial trauma patients. Med J Armed Forces India 2015;71(Suppl 2):S382–S388. DOI: 10.1016/j.mjafi.2014.09.014.
  28. Koos B, Godt A, Schille C, et al. Precision of an instrumentation-based method of analyzing occlusion and its resulting distribution of forces in the dental arch. J Orofac Orthop 2010;71(6):403–410. DOI: 10.1007/s00056-010-1023-7.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.