The Journal of Contemporary Dental Practice

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 13 , ISSUE 6 ( November-December, 2012 ) > List of Articles

RESEARCH ARTICLE

Do NiTi Instruments show Defects before Separation? Defects caused by Torsional Fatigue in Hand and Rotary Nickel-Titanium (NiTi) Instruments which Lead to Failure during Clinical Use

Sudhir Kumar, P Ratnakar, NV Murali Krishna Chakka, Sanjib Das, Anandamy Bagchi

Citation Information : Kumar S, Ratnakar P, Chakka NM, Das S, Bagchi A. Do NiTi Instruments show Defects before Separation? Defects caused by Torsional Fatigue in Hand and Rotary Nickel-Titanium (NiTi) Instruments which Lead to Failure during Clinical Use. J Contemp Dent Pract 2012; 13 (6):867-872.

DOI: 10.5005/jp-journals-10024-1243

Published Online: 01-04-2013

Copyright Statement:  Copyright © 2012; The Author(s).


Abstract

Aims

Visual and microscopic evaluation of defects caused by torsional fatigue in hand and rotary nickel titanium (NiTi) instruments.

Materials and methods

Ninety-six NiTi greater taper instruments which were routinely used for root canal treatment only in anterior teeth were selected for the study. The files taken include ProTaper for hand use, ProTaper Rotary files and Endowave rotary files. After every use, the files were observed visually and microscopically (Stereomicroscope at 10×) to evaluate the defects caused by torsional fatigue. Scoring was given according to a new classification formulated which gives an indication of the severity of the defect or damage.

Statistical analysis

Data was statistically analyzed using KruskallWallis and Mann-Whitney U test.

Results

Number of files showing defects were more under stereomicroscope than visual examination. But, the difference in the evaluation methods was not statistically significant. The different types of defects observed were bent instrument, straightening/stretching of twist contour and partial reverse twisting. Endowave files showed maximum number of defects followed by ProTaper for hand use and least in ProTaper Rotary.

Conclusion

Visible defects due to torsional fatigue do occur in NiTi instruments after clinical use. Both visual and microscopic examinations were efficient in detecting defects caused due to torsional fatigue. This study emphasizes that all files should be observed for any visible defects before and after every instrumentation cycle to minimize the risk of instrument separation and failure of endodontic therapy.

How to cite this article

Chakka NVMK, Ratnakar P, Das S, Bagchi A, Kumar S, Anumula L. Do NiTi Instruments show Defects before Separation? Defects caused by Torsional Fatigue in Hand and Rotary Nickel-Titanium (NiTi) Instruments which Lead to Failure during Clinical Use. J Contemp Dent Pract 2012;13(6):867-872.


PDF Share
  1. Rotary nickel titanium profile systems for preparing curved canal in resin blocks: Influence of operator on instrument breakage. Int Endodontic J 1999;32:436-43.
  2. Fatigue resistance of engine driven Rotary nickel titanium endodontic instruments. Journal of Endodontics 2002;28:765-69.
  3. Defects in rotary nickel titanium files after clinical use. Journal of Endodontics 2000;26:161-66.
  4. Cyclic fatigue of 3 types of rotary NiTi files in a dynamic model. Journal of Endodontics 2006;32:55-57.
  5. Influence of phase transformation on the torsional and bending properties of nickel titanium Rotary endodontic instruments. International Endodontic Journal 2006;39:119-26.
  6. Shaping ability of progressive versus constant taper instruments in simulated root canals. International Endodontic Journal 2006;39:791-99.
  7. International Endodontic Journal 2006;39:755-63.
  8. Torque during canal instrumentation using rotary nickel titanium files. Journal of Endodontics 2000;26:156-60.
  9. An analysis of clinical breakage of root canal instruments. Journal of Endodontics 1988;14:75-82.
  10. Microscopic evaluation of 3 endodontic files pre and post instruments. Journal of Endodontics 1998;24:461-64.
  11. Influence of rotational speed, torque in operator proficiency on failure of greaterTaper files. International Endodontic Journal 2002;35:7-12.
  12. Cyclic fatigue testing of nickel titanium endodontic instruments. Journal of Endodontics 1997;23:77-85.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.