The Journal of Contemporary Dental Practice

Register      Login

SEARCH WITHIN CONTENT

FIND ARTICLE

Volume / Issue

Online First

Archive
Related articles

VOLUME 15 , ISSUE 4 ( July-August, 2014 ) > List of Articles

RESEARCH ARTICLE

Clinical and Radiographic Evaluation of Narrow-Diameter Titanium-Zirconium Implants in Unilateral Atrophic Mandibular Distal Extensions: A 1-Year Pilot Study

Ali M El-Sheikh, Omar F Shihabuddin

Citation Information : El-Sheikh AM, Shihabuddin OF. Clinical and Radiographic Evaluation of Narrow-Diameter Titanium-Zirconium Implants in Unilateral Atrophic Mandibular Distal Extensions: A 1-Year Pilot Study. J Contemp Dent Pract 2014; 15 (4):417-422.

DOI: 10.5005/jp-journals-10024-1555

Published Online: 01-12-2014

Copyright Statement:  Copyright © 2014; The Author(s).


Abstract

Background

The use of endosseous dental implants has led to more sophisticated fixed options when considering treatment of patients with distal extensions. The use of narrow-diameter implants may reduce the necessity for bone augmentation. The mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable.

Purpose

The purpose of this study was to evaluate clinically and radiographically the performance of narrow-diameter bone level implants made from titanium-zirconium alloy (TiZr, RoxolidTM) in restoring unilateral atrophic mandibular distal extensions with fixed dental prostheses.

Materials and methods

Twenty partially edentulous patients with unilateral atrophic mandibular distal extensions received two 3.3 mm diameter bone level TiZr implants (Straumann AG, Basel, Switzerland). The two implants were restored with 3-units ceramo-metal fixed partial dentures. Standardized clinical and radiographic parameters (survival rate, probing pocket depth and marginal bone loss) were evaluated at the time of the completion of the prosthetic treatment (baseline) and after 3, 6 and 12 months of functional loading. Prosthetic complications were also assessed.

Results

The survival rate for narrow-diameter bone level TiZr implants was 100% after 1 year of functional loading. There were no statistically significant differences between the values of probing pocket depth over the follow-up period. All implants showed less than 1 mm of marginal bone loss at the end of the follow-up period.

Conclusion

Within the limitations of this 1-year pilot study, the use of narrow-diameter bone level TiZr implants appears to be predictable in restoring the unilateral atrophic mandibular distal extensions. This type of implants meets established success and survival criteria after 1 year.

How to cite this article

El-Sheikh AM, Shihabuddin OF. Clinical and Radiographic Evaluation of Narrow-Diameter Titanium-Zirconium Implants in Unilateral Atrophic Mandibular Distal Extensions: A 1-Year Pilot Study. J Contemp Dent Pract 2014;15(4):417-422.


PDF Share
  1. Implant-retained partial overdenture with resilient attachments. J Prosthodont 2008;17:141-148.
  2. Periodontal findings in patients 10 years after insertion of removable partial dentures. J Oral Rehabil 2001;28:991-997.
  3. The effect of removable partial dentures on periodontal health of abutment and non-abutment teeth. J Periodontol 2002;73:137-144.
  4. A clinical follow-up study of the periodontal conditions of RPD abutment and nonabutment teeth. J Oral Rehabil 2010;37:545-552.
  5. Clinical performance of cast clasp-retained removable partial dentures: a retrospective study. Int J Prosthodont 2012;25:138-144.
  6. Implants (3.3 mm diameter) for the rehabilitation of edentulous posterior regions: a retrospective clinical study with up to 11 years of follow-up. Clin Implant Dent Relat Res 2011;13:95-103.
  7. Clinical evaluation of small diameter straumann implants in partially edentulous patients: a 5-year retrospective study. J Dent (Tehran) 2011;8:75-80.
  8. Optimizing esthetics for implant restorations in the anterior maxilla: anatomic and surgical considerations. Int J Oral Maxillofac Implants 2004;19:43-61.
  9. A pilot study to evaluate the success and survival rate of titanium-zirconium implants in partially edentulous patients: results after 24 months of follow-up. Clin Oral Implants Res 2011;23:873-881.
  10. Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. Int J Prosthodont 1998;11:408-420.
  11. The extremely resorbed mandible: a comparative prospective study of a 2-year results with 3 treatment strategies. Int J Oral Maxillofac Implants 2004;19:563-577.
  12. Improved biocompatibility of titanium-zirconium (Ti-Zr) alloy: tissue reaction and sensitization to Ti-Zr alloy compared with pure Ti and Zr in rat implantation study. Mater Trans 2005;46:2260-2267.
  13. Mechanical properties of the binary titanium-zirconium alloys and their potential for biomedical materials. J Biomed Mater Res 1995;29:943-950.
  14. Evaluation of a new titanium-zirconium dental implant: a biomechanical and histological comparative study in the minipig. Clin Implant Dent Relat Res 2012;14:538-545.
  15. Tissue integration of a new titanium-zirconium dental implant: a comparative histologic and radiographic study in the canine. J Periodontol 2011;82:1453-1461.
  16. Bone apposition to a titanium-zirconium alloy implant, as compared to two other titanium-containing implants. Eur Cell Mater 2012;23:273-288.
  17. A comparison of biocompatibility and osseointegration of ceramic and titanium implants: an in vivo and in vitro study. Int J Oral Maxillofac Surg 2012;41:638-645.
  18. A double-blind randomized controlled trial (RCT) of titanium-13zirconium versus titanium grade IV small-diameter bone level implants in edentulous mandibles -results from a 1-year observation period. Clin Implant Dent Relat Res 2012;14:896-904.
  19. Titanium-zirconium alloy narrow-diameter implants (Straumann Roxolid(®)) for the rehabilitation of horizontally deficient edentulous ridges: prospective study on 18 consecutive patients. Clin Oral Implants Res 2012;23:1136-1141.
  20. Tissue integration of nonsubmerged implants. 1-year results of a prospective study with 100 ITI hollow-cylinder and hollow-screw implants. Clin Oral Implants Res 1990;1:33-40.
  21. Partial dentures. Br Dent J 1970;495-502.
  22. McCracken's Removable Partial Prosthodontics. China: Elsevier Mosby, 2005.
  23. Clinical evaluation of small-diameter ITI implants: a prospective study. Int J Oral Maxillofac Implants 2004;19:92-99.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.